This makes the strongest soft-tissue<br />
femoral fixation solution an easy fit<br />
for your patients.<br />
ENDOBUTTON<br />
INDICATOR<br />
Selection <strong>Device</strong><br />
ENDOBUTTON <strong>CL</strong><br />
<strong>ULTRA</strong><br />
<strong>Fixation</strong> <strong>Device</strong>
The ENDOBUTTON INDICATOR Selection <strong>Device</strong> helps you easily<br />
determine what size ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> <strong>Fixation</strong> <strong>Device</strong> to use<br />
in your A<strong>CL</strong> reconstructions. Ideal for anatomic or traditional A<strong>CL</strong><br />
reconstruction techniques, the ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> <strong>Device</strong> offers the<br />
strongest soft tissue femoral fixation currently available, and the highest<br />
failure load compared to competitive technologies.*<br />
Using the technique outlined in this brochure, the reusable ENDOBUTTON<br />
INDICATOR device takes into account femoral tunnel length, graft depth,<br />
and drilling depth – and indicates the appropriate ENDOBUTTON <strong>CL</strong><br />
device size. Compatible with the <strong>CL</strong>ANCY Anatomic Cruciate Guide/<br />
Flexible Drill System.<br />
Knobs lock sliding scale and<br />
passing pin safely in place.<br />
Femoral tunnel length<br />
ENDOBUTTON <strong>CL</strong> device size<br />
Pin allows easy suture<br />
passing for graft passage.<br />
Windows and sliding scale<br />
make it easy to read the<br />
femoral tunnel length and<br />
ENDOBUTTON <strong>CL</strong> device size.<br />
Calibrated passing pin includes<br />
a clearly labeled stop mark for<br />
femoral tunnel depth.<br />
The ENDOBUTTON INDICATOR Selection <strong>Device</strong> was developed by Dr. Bryce Bederka and Smith & Nephew.
ENDOBUTTON INDICATOR<br />
Selection <strong>Device</strong><br />
Technique<br />
Step 1<br />
Using a 2.4 mm or 2.7 mm passing pin,<br />
drill into femur until black line marked on<br />
pin (shown in inset) is flush with bone on<br />
lateral wall of femoral condyle in notch.<br />
Step 2<br />
Place INDICATOR device over passing pin<br />
until it touches bone of the lateral condyle.<br />
Lock passing pin in place with first locking<br />
knob, positioned on proximal end of device.<br />
Step 3<br />
Small window displays total femoral<br />
tunnel length.<br />
Step 4<br />
Read larger window to determine size of<br />
ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> <strong>Fixation</strong> <strong>Device</strong>,<br />
which is based on desired graft length.<br />
If femoral tunnel length is between sizes,<br />
select next smaller device size to maximize<br />
amount of graft in tunnel.<br />
Step 5<br />
Using 4.5 ENDOBUTTON drill, drill all the<br />
way through femur, ensuring that drill breaks<br />
through cortex.<br />
Step 6<br />
Drill socket to the displayed drilling depth<br />
(which includes 10 mm flipping distance<br />
for fixation device). Attach passing suture<br />
to eyelet of passing pin. Then, remove<br />
INDICATOR device and pin with passing<br />
suture for later graft passage.
Selection <strong>Device</strong><br />
Proprietary and Confidential: Do not disclose, copy, distribute, or<br />
otherwise reproduce this information without the written consent<br />
of an officer of Smith & Nephew.<br />
ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> <strong>Fixation</strong> <strong>Device</strong><br />
Efficient<br />
Preloaded with <strong>ULTRA</strong>BRAID #5 lead<br />
suture and DURABRAID #5 flipping suture<br />
for procedural efficiency.<br />
Continuous loop (<strong>CL</strong>) of suture<br />
Offers the strongest soft tissue femoral fixation<br />
currently available, and the highest failure load<br />
compared to competitive technologies.*<br />
Ordering Information<br />
Reference Number Name<br />
72202544 ENDOBUTTON INDICATOR Selection <strong>Device</strong><br />
Accommodates various graft lengths<br />
The one-size titanium button is available with<br />
pre-measured loops available in 10 different<br />
sizes, from 15 mm to 60 mm.<br />
Associated Laser-marked Passing Pins<br />
014508 2.7 mm Drill Tip passing pin<br />
7207220 2.4 mm Trocar Tip passing pin<br />
7208678 2.4 mm Drill Tip passing pin<br />
72201594 2.4 mm Flexible Passing Pin<br />
ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> <strong>Fixation</strong> <strong>Device</strong><br />
72200146 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 15 mm<br />
72200147 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 20 mm<br />
72200148 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 25 mm<br />
72200149 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 30 mm<br />
72200150 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 35 mm<br />
72200151 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 40 mm<br />
72200152 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 45 mm<br />
72200153 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 50 mm<br />
72200154 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 55 mm<br />
72200155 ENDOBUTTON <strong>CL</strong> <strong>ULTRA</strong> System 60 mm<br />
Educational Materials<br />
10600611 ENDOBUTTON INDICATOR Selection <strong>Device</strong><br />
Surgical Technique Animation DVD<br />
©2009 Smith & Nephew 12/09 106006 1 Rev. A<br />
Technique Animation<br />
*smith&nephew<br />
ENDOBUTTON<br />
INDICATOR<br />
* July 2007 data on file at Smith & Nephew. This is the most current test data and competitive product information.<br />
Endoscopy<br />
Smith & Nephew, Inc.<br />
150 Minuteman Road<br />
Andover, MA 01810 USA<br />
www.smith-nephew.com<br />
T +1 978 749 1000<br />
US Customer Service: +1 800 343 5717<br />
International Customer Service: +1 978 749 1140<br />
Trademark of Smith & Nephew. Certain marks<br />
Registered US Patent and Trademark Office.<br />
©2010 Smith & Nephew. All rights reserved.<br />
Printed in USA. 04/10 10600557 Rev. A