STATUS INDICATORS<br />
When the following indicators light up or blink on the operation panel or the following<br />
alphanumeric codes appear in the display, solve the problem immediately referring<br />
to both the table below and the relevant page.<br />
Be sure to use only genuine SHARP parts and supplies.<br />
Indication Cause and remedy Page<br />
Steadily Replacement of drum cartridge will be needed Start<br />
Drum replacement<br />
lit soon. Prepare a new cartridge.<br />
Guide<br />
required indicator<br />
Blinking Drum cartridge must be replaced. Replace it with a new one. 70<br />
TD cartridge Steadily Replacement of TD cartridge will be needed Start<br />
replacement lit soon. Prepare a new cartridge.<br />
Guide<br />
required indicator Blinking TD cartridge must be replaced. Replace it with a new one. 69<br />
Misfeed indicator Blinking<br />
A misfeed has occurred. Remove the misfed paper<br />
referring to the description of "MISFEED REMOV<strong>AL</strong>".<br />
83<br />
Steadily<br />
When the document feeder cover is open.<br />
lit<br />
–<br />
SPF misfeed<br />
indicator<br />
Power save indicator is<br />
steadily lit.<br />
Blinking<br />
The paper tray indicator is<br />
blinking.<br />
"CH" is blinking in the display.<br />
"CH" is steadily lit in the<br />
display.<br />
press the start (<br />
"OP" is blinking in the display.<br />
"P" is blinking in the display.<br />
A letter and a number appear<br />
alternately.<br />
An original misfeed has occurred in the SPF. Remove<br />
the misfed originals referring to the description of<br />
"D: Misfeed in the SPF (<strong>AL</strong>-<strong>2041</strong>)".<br />
The unit is in the preheat mode. Press any key to<br />
cancel the preheat mode.<br />
The unit is in the auto power shut-off mode. Press<br />
the start ( ) key to cancel the auto power shutoff<br />
mode.<br />
The paper tray is not pushed in correctly, or there<br />
is no paper in the tray. Push the tray all the way<br />
in or load paper in the tray.<br />
The TD cartridge is not installed. Check if the<br />
cartridge is installed.<br />
Push the cartridge in until it locks securely in<br />
place.<br />
Side cover is open. Close the side cover securely<br />
by pressing the round projections near the side<br />
cover open button.<br />
This appears if it is detected that the original<br />
cover/SPF is open when copying is started.<br />
Completely close the original cover/SPF, or<br />
) key again.<br />
Depending on the colour and the density of the<br />
original, "OP" blinking may appear even when<br />
the original cover/SPF is closed. In such a case,<br />
press the start key again to make a copy.<br />
The paper tray or multi-bypass tray is empty.<br />
Load paper.<br />
A misfeed has occurred in the paper tray or<br />
multi-bypass tray. Remove the misfed paper.<br />
The unit will not function. Turn the power switch<br />
off, remove the power cord from the outlet, and<br />
contact your authorised service representative.<br />
87<br />
64<br />
64<br />
–<br />
Start<br />
Guide<br />
–<br />
–<br />
10, 12<br />
83<br />
–<br />
9<br />
82