DIVISION EIGHT – PARKING REGULATIONS<br />

P<br />

Neighbourhood Commercial Snow Storage<br />

(10) The provision <strong>of</strong> snow storage areas for snow removed from an outdoor<br />

parking area in the Neighbourhood Commercial zone shall:<br />

(a) be located within 10.0 m <strong>of</strong> these parking areas; and<br />

(b) equal 50% <strong>of</strong> the size <strong>of</strong> the parking area; however,<br />

(c) this requirement for snow storage areas may be waived upon<br />

confirmation <strong>of</strong> an <strong>of</strong>f-site snow storage dump or where a<br />

subterranean heating system is installed for parking areas.<br />

805. Commercial Loading Standards<br />

(1) Where any commercial building is being erected, enlarged or increased in<br />

capacity, <strong>of</strong>f-street loading spaces shall be provided in accordance with<br />

Section 805(2) <strong>of</strong> this bylaw.<br />

(2) One <strong>of</strong>f-street loading space shall be provided for every 2,000.0 m² <strong>of</strong><br />

commercial uses in a building or combination <strong>of</strong> commercial<br />

establishments involving the receipt and delivery <strong>of</strong> goods and every<br />

fractional unit shall require the addition <strong>of</strong> one loading space.<br />

(3) Pursuant to Section 906(6) <strong>of</strong> the “Local Government Act”, a consideration<br />

<strong>of</strong> all uses in the subject building and their loading requirements as outlined<br />

in this Division shall be required and implemented where an addition to an<br />

existing building for an additional room(s) will increase the gross floor area<br />

by more than 10% and where a Building Permit is required pursuant to the<br />

“<strong>Regional</strong> <strong>District</strong> <strong>of</strong> <strong>North</strong> <strong>Okanagan</strong> Building <strong>Bylaw</strong> No. 1747, 2003”.<br />

(4) All loading spaces shall be provided on the parcel where the subject<br />

building or use is situated.<br />

(5) A loading space shall not be less than 9.0 m long, 2.4 m wide and 3.7 m in<br />

height.<br />