Enabled the high current charging option will set 700mA charging in the<br />

power supply system of the reader expander.<br />

For reader expanders that do not have a power supply this option performs<br />

no function.<br />

Disabled the reader expander will set the standard 350mA charging in the<br />

power supply system.<br />

Option 2 - Multiple Reader Connected to Port 1<br />

Enabled the reader will process the multiplexed reader inputs on Port 1 so<br />

that dual readers can be connected for entry and exit processing. The<br />

duplex reader that is connected will always operate as the exit reader.<br />

Disabled the reader port 1 interface will operate as a single reader input.<br />

Option 3 - Multiple Reader Connected to Port 2<br />

Enabled the reader will process the multiplexed reader inputs on Port 2 so<br />

that dual readers can be connected for entry and exit processing. The<br />

duplex reader that is connected will always operate as the exit reader.<br />

Disabled the reader port 2 interface will operate as a single reader input.<br />

Option 4 – Virtual Module<br />

Enabled a physical module can’t register at this address. This is used to<br />

protect Zones, PGM’s etc that are used by functions.<br />

Disabled modules can register as normal.<br />

Option 5 – Invert Module Tamper<br />

Enabled the reader expander will invert the module tamper input allowing a<br />

normally open (door closed) tamper switch to be used.<br />

Disabled the reader expander will use the standard normally closed (door<br />

closed) tamper switch.<br />

Option 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Reader Port 1 Mode<br />

The reader mode setting determines what function the reader attached to port one will<br />

perform.<br />

RD001 R1 Mode<br />

Access<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />