Enabled the high current charging option will set 700mA charging in the<br />

power supply system.<br />

For PGM expanders that do not have a power supply this option performs no<br />

function.<br />

Disabled the high current option will set the standard 350mA charging rate<br />

in the power supply system.<br />

Option 2 – Invert Module Tamper<br />

Enabled the PGM expander will invert the module tamper input allowing a<br />

normally open (door closed) tamper switch to be used.<br />

Disabled the PGM expander will use the standard normally closed (door<br />

closed) tamper switch.<br />

Option 3 – Stage PGM On/Off<br />

Enabled the PGM expander will not activate any two local PGMs within 50ms<br />

of each other. E.g. If PGM’s 1 to 4 were activated at the same time the<br />

PX16 would activate PGM 1 first then delay 50ms and activate PGM 2,<br />

cotinuting like this until all 4 PGMs were activated.<br />

Disabled the PGM expander will turn on or off all PGM’s instantly.<br />

Option 4 – Virtual Module<br />

Enabled a physical module can’t register at this address. This is used to<br />

protect Zones, PGM’s etc that are used by functions.<br />

Disabled modules can register as normal.<br />

Option 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Reader Expander<br />

To access the Reader Expander module programming login using a valid installer code and<br />

then select [MENU, 4, 1, 3]. The screen displays “Reader exp to modify” as shown in the<br />

following example.<br />

2 Reader Exp to<br />

modify: RD001<br />

Every time you press the Enter key, the next screen appears. The different screens are<br />

described in the following sub-sections. Programming the Reader Expander allows you to set<br />

the polling time of the module, power supply options and the configuration of the readers with<br />

associated doors.<br />

89 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>