11-14-72-B9 Serial Number of the registered keypad at this address.<br />

[23] The current polling timeout value.<br />

V 1.05<br />

Software version of the registered keypad.<br />

2404 Software build number.<br />

R<br />

The PGM expander is registered<br />

('*' will indicate no expander registered)<br />

O<br />

The PGM expander is online<br />

('*' will indicate the expander is offline)<br />

To view the IP address of the module press the [] key from this view. If the module is<br />

connected over the RS-485 LAN “---.---.---.---“ will be displayed.<br />

To list all offline or online modules refer to the Module Network Functions on Page 265.<br />

Special functions are provided to update and update reset a module individually by using a<br />

shortcut key directly from the keypad selection screen.<br />

Key<br />

[STAY]<br />

[FORCE]<br />

Function<br />

Pressing the [STAY] key will update the PGM expander number that is<br />

currently displayed in the module selection window. This will program<br />

the module WITHOUT resetting the module.<br />

Pressing the [FORCE] key will update and init the PGM expander<br />

number that is currently displayed in the module selection window. This<br />

will program the module and then restart the module.<br />

Module Polling Time<br />

The polling time defines how often the PGM expander module checks in with the Protégé<br />

System <strong>Controller</strong>. If a PGM expander fails to check in, it triggers its associated<br />

communication failure trouble zone (PXxxx:08) and the trouble zone for a general module<br />

communications failure.<br />

To enter a polling time (008 to 250 seconds), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER]. By default the PGM expander polling time<br />

is set to 250 seconds. Setting a polling time below 60 seconds should only be done for PGM<br />

expanders that are in a non-secure area.<br />

PX001 Polling<br />

time: 250 secs<br />

For UL and cUL listed installations you MUST set the polling time to 180 seconds or<br />

less.<br />

PGM Expander Module Options<br />

Options that relate to the PGM expander module can be set using option entry.<br />

PX001 Module<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - High Current Charging<br />