To enter a polling time (008 to 250 seconds), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER]. By default the Zone Expander polling time<br />

is set to 250 seconds. Setting a polling time below 60 seconds should only be done for zone<br />

expanders that are in a non-secure area.<br />

ZX001 Polling<br />

time: 250 secs<br />

For UL and cUL listed installations you MUST set the polling time to 180 seconds or<br />

less.<br />

Zone Expander Module Options<br />

Options that relate to the zone expander module can be set using option entry.<br />

ZX001 Module<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - High Current Charging<br />

Enabled the zone expander will enable 700mA charging in the power supply<br />

system.<br />

Disabled the zone expander will enable 350mA charging in the power supply<br />

system.<br />

Option 2 – Virtual Module<br />

Enabled a physical module can’t register at this address. This is used to<br />

protect Zones, PGM’s etc that are used by functions.<br />

Disabled modules can register as normal.<br />

Option3 – Invert Module Tamper<br />

Enabled the zone expander will invert the module tamper input allowing a<br />

normally open (door closed) tamper switch to be used.<br />

Disabled the zone expander will use the standard normally closed (door<br />

closed) tamper switch.<br />

Option 4, 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />