Option 3 - Event Review Menu<br />

Enabled the keypad will allow access to the Event Review Menu if no user is<br />

logged in and a user press's the [MENU] key.<br />

Disabled the keypad will not allow access to the Event Review Menu offline.<br />

Option 4 - Keypad Information Menu<br />

Enabled the keypad will allow access to the Keypad Information Menu if no<br />

user is logged in and a user press's the [MENU] key. It is recommended to<br />

leave this option enabled.<br />

Disabled the keypad will not allow access to the Keypad Information Menu<br />

offline.<br />

Option 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Zone Expander<br />

To access the Zone Expander module programming login using a valid installer code and then<br />

select [MENU, 4, 1, 2]. The screen displays “Zone exp to modify” as shown in the following<br />

example.<br />

16 Zone Exp to<br />

modify: ZX001<br />

Every time you press the Enter key, the next screen appears. The different screens are<br />

described in the following sub-sections. Programming the Zone Expander allows you to set<br />

the polling time of the module and power supply options.<br />

When programming modules some options are processed at the module, for these options to<br />

operate correctly a network update must be performed and the zone expander must be<br />

registered and online.<br />

Updating modules can be accessed by selecting [MENU, 4, 8, 1, 3], you can also check the<br />

status of your modules by selecting [MENU, 4, 8, 1, 1] for all modules presently offline and<br />

[MENU, 4, 8, 1, 2] for all online modules. For more information refer to the advanced menu<br />

section on page XXX.<br />

Selecting a Zone Expander to Modify<br />

Each zone expander is assigned a unique address from 001 to 250. Programming the address<br />

of the Zone Expander Module (<strong>PRT</strong>-ZX16) is covered in the installation instructions included<br />

with your <strong>PRT</strong>-ZX16 Zone Expander Module.<br />

16 Zone Exp to<br />

modify: ZX001<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />

84