defer warning keypad group.<br />

Disabled the keypad will not display any defer messages regardless of the<br />

defer area keypad group.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Keypad Access Options<br />

Options that relate to the keypad access control functions and some specific area control<br />

menu settings.<br />

KP001 Access<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options on Page 409.<br />

Option 1 - Unlock Controlled Door<br />

Enabled the keypad will allow a user to unlock the controlled door by<br />

pressing the [FUNCTION] key.<br />

Disabled the keypad performs no action when the function key is pressed<br />

and held. The function key may still be used for home automation or control<br />

functions if enabled for the keypad.<br />

Option 2 - Strict Primary Area Status Display<br />

Enabled the keypad will only display the primary area and will not show ANY<br />

other areas regardless of the programmed options for the logged in user or<br />

the keypad security settings.<br />

Disabled the keypad will function normally using the area configuration and<br />

user area settings.<br />

Option 3 - 24 Hour Area Access<br />

Enabled the keypad will allow the 24Hr status screen of an area to be<br />

accessed by pressing the [] key when the user is logged in and at the<br />

area display screen. The user must have the 24Hr menu option set.<br />

Disabled the keypad will not display the 24 Hour area status screen.<br />

Option 4 - Area Group Access<br />

Enabled the keypad will allow the area group access screen to be accessed<br />

by pressing the [] key when the user is logged in and at the area display<br />

screen.<br />

Disabled the keypad will not allow access to the area groups screen.<br />

Option 5 - Unlock Assigned Door Offline<br />

Enabled the keypad will allow the [FUNCTION] key to be pressed and held<br />

generating an unlock request for the assigned door. This can be<br />