Option 3 - Area Group Status Display<br />

Enabled the keypad will display the status of the area's that are assigned in<br />

the area group. Each area is presented on screen and can be scrolled using<br />

the [] and [] keys.<br />

Disabled the keypad will not display the area group status.<br />

Option 4 - Trouble Display<br />

Enabled the keypad will lockout any user activity for the programmed<br />

lockout time if three invalid PIN numbers are entered. This option will have<br />

no affect if the lockout time is programmed to 0 seconds.<br />

Disabled the keypad will perform no action on an invalid PIN.<br />

Option 5 - Bypassed Zone Display<br />

When enabled the keypad will display the message zone(s) bypassed when<br />

a zone has been bypassed in the system or primary area depending on the<br />

setting of option 7. Bypassed zones can be viewed by going to the bypass<br />

view menu [MENU, 5, 2]. This option can be programmed to only show the<br />

primary area bypassed zones by setting option 7.<br />

Disabled the keypad will not show the bypassed zones message.<br />

Option 6 - Alarm Memory Display<br />

When enabled the keypad will display the message alarm(s) in memory.<br />

Alarms can be viewed by going to the alarm view menu [MENU, 5, 1]. This<br />

option can be programmed to only show the primary area alarms by setting<br />

option 7.<br />

Disabled the keypad will show not show the alarm memory status.<br />

Option 7 - Display Only Primary Area<br />

When enabled with option 6 being enabled the keypad will only display the<br />

bypassed zone status and alarm memory for the primary area of the<br />

keypad.<br />

Setting this option with option 7 means that ONLY the primary area's alarms<br />

is shown. In which case, the alarm message is cleared ONLY if the primary<br />

area's memory is acknowledged.<br />

If option 7 is not turned on then ANY area that has an alarm stored in<br />

memory is shown and ALL the areas' memory must be acknowledged before<br />

this message is cleared.<br />

Disabled the keypad will display the alarm memory and bypassed zones in<br />

the system.<br />

Option 8 - Display Area Defer Arming Warnings<br />

When enabled the keypad will allow defer messages to be shown on the<br />

keypad for any area that is in the defer mode and the keypad is part of the<br />

81 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>