Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the<br />

schedule displayed. For more information about the list control data entry refer to the section<br />

List Control Data Entry on Page 406.<br />

Secondary Elevator Group<br />

A secondary elevator group can be selected that will be used when the schedule of the<br />

elevator group that is programmed is not valid. The schedule of the secondary elevator group<br />

must be valid or set to none. The secondary elevator group allows very powerful elevator<br />

group controls to be placed on users during certain times of the day preventing access to<br />

certain elevators.<br />

EG001 Secondary<br />

None<br />

Use the [1] and [3] keys to scroll the secondary elevator group selection and press [ENTER]<br />

to select the elevator group displayed. For more information about the list control data entry<br />

refer to the section List Control Data Entry on Page 406. Programming a secondary elevator<br />

group that uses the current elevator group being edited will perform no function.<br />

Elevator Group Assignment Blocks 1 to 32<br />

The elevator group assignment blocks assign an elevator car to the group that is being<br />

programmed. Each block is 8 elevators and the number of elevator blocks that can be<br />

programmed depends on the number of elevators that the system is configured to manage.<br />

For example if there are 16 elevators there will be 2 blocks of 8 elevators. Block 1 option 1<br />

will refer to Elevator 001 and Block 2 Option 8 will refer to Elevator 016.<br />

EG001 Block 1<br />

[12345678]<br />

To modify the block setting options, follow the settings as explained in section Entering Data<br />

Options on Page 409.Use the relevant key from 1 to 8 to toggle the elevator for the block.<br />

Pressing the [ENTER] key will move you to the next block in the elevator group until you<br />

return to the elevator group selection.<br />

The following table shows the relationship between the block and the elevator that is being<br />

selected for the elevator group. For example if you want to select Elevator 12 you would go to<br />

block 2 and then press [4] to toggle the option.<br />

Block Opt Opt Opt Opt Opt Opt Opt Opt<br />

# 1 2 3 4 5 6 7 8<br />

1<br />

Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />

001 002 003 004 005 006 007 008<br />

2<br />

Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />

009 010 011 012 013 014 015 016<br />

3<br />

Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />

017 018 019 020 021 022 023 024<br />

4<br />

Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />

025 026 027 028 029 030 031 032<br />

5<br />

Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />

033 034 035 036 037 038 039 040<br />

6 Elevator Elevator Elevator Elevator Elevator Elevator Elevator Elevator<br />