Disabled the access level PGM will perform no function.<br />

Option 3 - Validate Access Level If Qualify PGM is on<br />

Enabled the access level will only be valid if the qualify PGM programmed in<br />

the qualify PGM entry screen is turned on.<br />

For this option to work, the Qualify PGM must be programmed with a valid<br />

PGM number. If option 3 and 4 are enabled only option 3 will be used.<br />

Disabled the qualify PGM will not be checked.<br />

Option 4 – Validate Access Level If Qualify PGM is off<br />

Enabled the access level will only be valid if the qualify PGM programmed in<br />

the qualify PGM entry screen is turned off.<br />

For this option to work, the Qualify PGM must be programmed with a valid<br />

PGM number. If option 3 and 4 are enabled only option 3 will be used.<br />

Disabled the qualify PGM will not be checked.<br />

Option 5, 6, 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Activation PGM or PGM Group<br />

You can assign a PGM or PGM group to activate whenever a user performs a valid action from<br />

an LCD Keypad or when a user is granted access after presenting their access control card to<br />

a reader in the system. The assigned PGM or PGM group only activates if the action<br />

performed by the user is permitted by the assigned access level.<br />

AL001 Select<br />

pgm: --000:00<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and<br />

PGM Groups on Page 410.<br />

Use the PGM and PGM groups for basic elevator control of up to 8 floors. This provides a very<br />

simple elevator control solution. For more complex elevator control use the elevator control<br />

features.<br />

Activation PGM Time<br />

You can override the programmed activation time for a PGM by setting an activation time in<br />

the access level.<br />

AL001 PGM On<br />

time: 00000 secs<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and<br />

PGM Groups on Page 410.<br />