01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Door Group Name<br />

If the selected door group has a name associated (some door groups do not have a name<br />

associated with them) the name programming screen will be shown.<br />

DG001 Name<br />

All Doors<br />

To scroll door groups by name use the [] and [] keys. To modify or enter a new name for<br />

the selected door group use the keypad as explained in section Entering Text and Names on<br />

Page 406 and press [ENTER].<br />

By default the door group name will be prefixed by an '*' this indicates that the name is an<br />

editable name in the system.<br />

Operating Schedule<br />

The operating schedule for the door group determines when the door group is valid and if it<br />

will use a secondary door group if the schedule is not valid. A schedule is a series of times<br />

and days that can be programmed to prevent the operating of functions based on a 7 day<br />

week and 24 hour clock. For more information on the programming of the schedule refer to<br />

the Schedule Programming section on Page 344.<br />

DG001 Schedule<br />

None<br />

Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the<br />

schedule displayed. For more information about the list control data entry refer to the section<br />

List Control Data Entry on Page 406.<br />

Secondary Door Group<br />

A secondary door group can be selected that will be used when the schedule of the door<br />

group that is programmed is not valid. The schedule of the secondary door group must be<br />

valid or set to none. The secondary door group allows very powerful door group controls to be<br />

placed on users during certain times of the day preventing access to certain doors.<br />

DG001 Secondary<br />

None<br />

Use the [1] and [3] keys to scroll the secondary door group selection and press [ENTER] to<br />

select the door group displayed. For more information about the list control data entry refer<br />

to the section List Control Data Entry on Page 406. Programming a secondary door group that<br />

uses the current area group being edited will perform no function.<br />

Door Group Assignment Blocks 1 to 32<br />

The door group assignment blocks assign a door to the group that is being programmed. Each<br />

block is 8 doors and the number of door blocks that can be programmed depends on the<br />

number of doors that the system is configured to manage. For example if there are 64 doors<br />

there will be 8 blocks of 8 doors. Block 1 option 1 will refer to Door 001 and Block 8 Option 8<br />

will refer to Door 064.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />