UN00001 Misc<br />

[1-34----]<br />

To modify options, use the follow the settings as explained in section Entering Data Options<br />

on Page 409.Use the relevant key from 1 to 8 to toggle the state of the option.<br />

Option 1 - Greeting Mode<br />

Enabled the user will be presented on the keypad screen with a time of day<br />

greeting when they log in to the keypad. For example "Good Morning Mr.<br />

Smith" or "Good Afternoon Mr. Jones".<br />

Disabled the user will not be shown a greeting when they log in to the<br />

keypad.<br />

This option when enabled can be overridden by the same option in the<br />

menu group. To control this option per individual user disable the<br />

option in the menu group and assign this option for each user that<br />

requires a greeting message displayed on login.<br />

Option 2 - Menu Mode<br />

Enabled the user will be taken directly to the menu. Normally a user will be<br />

shown the status of the current area that the keypad belongs to however<br />

this feature allows users that can not perform any area commands or that<br />

are more likely to perform menu commands to be taken directly to the<br />

menu without pressing the [MENU] key when they log in.<br />

Disabled the user will be taken to the primary area status screen if they<br />

have access to the programmed area.<br />

Option 3 - Alarm Acknowledgement Allowed<br />

Enabled the user can acknowledge and delete alarms that are stored in<br />

memory for an area by using the [ENTER] key. To acknowledge alarms, the<br />

user must have access to the View menu. The area where the alarm<br />

occurred must also belong to the user’s disarm area group.<br />

Disabled the user will not be able to acknowledge alarms.<br />

This option when enabled can be overridden by the same option in the<br />

menu group. To control this option per individual user disable the<br />

option in the menu group and assign this option for each user.<br />

Option 4 - Show Alarm Memory On Login<br />

Enabled the user when logging in to the keypad will be displayed any<br />

existing alarm for the keypad’s primary area. If an alarm occurred in any<br />

other area, the alarm memory is sent to the alarm buffer, which can be<br />

viewed through the View menu. To view the alarm memory, the user must<br />

be allowed to access the View menu. The keypad’s primary area must also<br />

belong to the user’s disarm area group. If you want to acknowledge the<br />

alarm, the Alarm Acknowledgement option must be turned on.<br />

Disabled the keypad will take no action if alarm memory is present when a<br />

user logs in.<br />