User Area<br />

The user area can be used to disarm the selected area automatically on login to a keypad or<br />

when access is granted at a door or reader. For this feature to operate correctly the<br />

programmed area must belong to the user’s disarm area group. This feature is ideal for<br />

securing many individual offices yet arming all of them when all employees exit and disarming<br />

only the person’s office that they are allowed to access while other offices remain secure and<br />

protected.<br />

UN00001 Area<br />

None<br />

Use the [1] and [3] keys to scroll the user area selection and press [ENTER] to select the<br />

area that is displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

User Expiry Date<br />

Setting an expiry date for the user will prevent the user from gaining access to the system<br />

past the date that is set. Use this feature to program cards for temporary employees, trade<br />

people or contractors. This feature can also be used for membership processing to prevent<br />

access once the membership period has expired.<br />

UN00001 Expiry<br />

date: --/--/----<br />

Use the numerical keys to enter a valid date and then press [ENTER] to program the date. If<br />

you do not program a time in the following section the user will expire at midnight on the<br />

date that is programmed. For more information about entering the date information refer to<br />

the section Date and Time Data Entry on Page 407.<br />

If you do not enter a valid date an error message will be shown, pressing the [STAY] key will<br />

allow you to clear your entry or set the default value.<br />

User Expiry Time<br />

Setting an expiry time for the user will prevent the user from gaining access to the system<br />

past the date and time that is set. If you have created a temporary user by programming the<br />

expiry date in the previous screen, use the 24-hour clock method (i.e. 4:15pm = 16:15) to<br />

program the time that the user code (PIN) and its programmed rights become invalid. If the<br />

expiry date in the previous screen is left blank, the system ignores the time.<br />

If the time screen is left blank, but an expiry date has been programmed, the user code (PIN)<br />

expires at 23:59.59 on the date programmed.<br />

If the Loiter Mode option is turned on for this user, the expiry time is ignored and the user<br />

code (PIN) expires at 23:59.59 on the programmed date.<br />

Use this feature to program cards for temporary employees, trade people or contractors. This<br />

feature can also be used for membership processing to prevent access once the membership<br />

period has expired.<br />

UN00001 Expiry<br />

time: --:--<br />