01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

User Access Code or PIN Number<br />

The user code (PIN) can be from 1 to 8 digits in length. Entering a user code (PIN) that<br />

already exists in the system results in the system generating an error and alerting the owner<br />

of that code. To modify or enter a new pin number for the selected user follow the<br />

instructions in the section Entering PIN Numbers on Page 406 and press [ENTER].<br />

UN00001 Enter<br />

code: 123456<br />

For users to modify their own code or the code of another user with the same access level,<br />

the appropriate code modification options must be turned refer to User Options on Page X.<br />

Access Level Assignment<br />

The access level determines what rights this user will have in the protégé system. For more<br />

information on the programming of the access level refer to the Access Level Programming<br />

section on Page 60. Each user can be assigned four different access levels, when a user<br />

requests a certain action the protégé system checks each of the access levels in order until it<br />

finds one that has rights to perform the requested action. Each access level can also be<br />

assigned an independent start and end time.<br />

UN00001 Access<br />

*Access Lvl 001<br />

Use the [1] and [3] keys to scroll the access level selection and press [ENTER] to select the<br />

access level displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Access Level 1 Start Date<br />

Setting the access level start date will disable the access level for this user until 00:00 on this<br />

date. If a start time is also set the access level will be disabled until that time has past on<br />

this date.<br />

UN00001 Axs1 Sta<br />

date: --/--/----<br />

Use the numerical keys to enter a valid date and then press [ENTER] to program the date. If<br />

you do not program a time in the following section the access level will expire at midnight on<br />

the date that is programmed. For more information about entering the date information refer<br />

to the section Date and Time Data Entry on Page 407.<br />

If you do not enter a valid date an error message will be shown, pressing the [STAY] key will<br />

allow you to clear your entry or set the default value.<br />

Access Level 1 Start Time<br />

Setting the access level start time will disable the access level for the user until this time has<br />

past. If both the start time and date are set then the access level will remain disabled until<br />

the date and time has past. If only the time is set then the access level will be disabled until<br />

this time has past and will then remain enabled until either the access level end time expires<br />

or until the midnight of that day.<br />

41 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>