1. Set battery<br />

charge 700mA: N<br />

To change this option press the [1] key or to scroll the options press the [] and [] arrow<br />

keys. To return to the options screen press the [STAY] key. To save the options move off the<br />

screen using a navigation key or press the [ENTER] key.<br />

PGM and PGM Group Entry<br />

PGM and PGM Group Entry is done by selecting the module type and then the address and<br />

actual PGM number on the device. For example to program the second lock output on the<br />

fourth reader expander you would enter RD004:02 where the RD is entered using the ascii<br />

mode similar to the text entry and the 004 and 02 are entered using normal decimal mode<br />

entry.<br />

In the following example we will program the Green LED on the LCD keypad at address 001 to<br />

activate when the area is disarmed. We program this option in the area configuration.<br />

AR001 Disarmed<br />

pgm: --000:00<br />

In the above screen the default value for a PGM is shown this is –000:00. To default the PGM<br />

entry press the [DISARM] key or to recall the currently programmed value press the [ARM]<br />

key. Pressing the [5] key twice will put a ‘K’ in the first location. Using the table in the Object<br />

Notation Section on Page 402 the keypad is referenced as a KP. Press the [] arrow key to<br />

move to the next location.<br />

AR001 Disarmed<br />

pgm: K-000:00<br />

Pressing the [7] key once will show the ‘P’ on the screen, move the cursor to the right using<br />

the [] key.<br />

AR001 Disarmed<br />

pgm: KP000:00<br />

Complete the entry by pressing [0], [0], [1] then the PGM output number by pressing [0]<br />

and [3] for the green LED.<br />

To enter a PGM group complete the same procedures as above however use the PG for the<br />

prefix in the module type, the screen will change to only have 3 digits allowing the PGM group<br />

to be entered. See below for an example of PGM group 4 at the same location as above.<br />

AR001 Disarmed<br />

pgm: PG004<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />