DATA ENTRY<br />

Introduction<br />

When programming the Protégé System using the LCD Keypad the information is entered<br />

using predefined methods, these include List Entry (a list of predefined values or values<br />

looked up from another record), Decimal Entry, PGM and PGM Group, Protégé Notation and<br />

Module Notation. Each of these entry methods use predefined keys and functions as outlined<br />

in the following sections.<br />

Decimal Data Entry<br />

Decimal numbers are entered using the 0-9 keys. Pressing the [STAY] key will set the<br />

minimum value, pressing the [FORCE] key will set the maximum value and pressing the<br />

[ARM] will recall the value that was previously set.<br />

Decimal entry can take on any number of digits from 1 up to 32 depending on the location<br />

that the number is being entered. In the following example a number of 120 is being entered<br />

in to the door unlock time.<br />

DR001 Unlock<br />

time: 120 secs<br />

When you enter in to a decimal entry screen the cursor will be located on the first decimal<br />

digit that can be set. For our example the default door time is 005 seconds however we want<br />

to set the unlock time to 120.<br />

DR001 Unlock<br />

time: 005 secs<br />

In the above screen the cursor will be flashing over the first 0 of the 005 press the [1] key,<br />

the 0 will be replaced with a 1 and the cursor will move to the right over the next 0.<br />

DR001 Unlock<br />

time: 105 secs<br />

Pressing the [2] will replace the 0 with a 2 and then the cursor will move to the right once<br />

again and be positioned over the 5 now press the [0] and the completed value will be seen<br />

on the screen of 120 as shown below.<br />

DR001 Unlock<br />

time: 120 secs<br />

Once the information is entered as above the data is not saved until you move to another<br />

screen. Once you have moved off the screen by pressing the [ENTER] key or pressing the<br />

right, left, up or down key the data is saved.<br />