CP001:20 Ethernet Link Lost Hardware Fault System<br />

CP001:21 DVAC Line<br />

Hardware Fault System<br />

Fault/Polling Error<br />

CP001:22 ModBUS<br />

Hardware Fault System<br />

Communication Fault<br />

CP001:23 Protégé SMGT Remote Hardware Fault System<br />

Access<br />

CP001:24 Installer Logged In Hardware Fault System<br />

CP001:25 Service 1 Stopped Hardware Fault System<br />

CP001:26 Service 2 Stopped Hardware Fault System<br />

CP001:27 Service 3 Stopped Hardware Fault System<br />

CP001:28 Service 4 Stopped Hardware Fault System<br />

CP001:29 Reserved * *<br />

| | | | | | | |<br />

CP001:64 Reserved * *<br />

In the above table a '*' indicates that the trouble zone will not generate a system trouble as<br />

by default it is not assigned a trouble type or group. This can be done if required but is not<br />

recommended.<br />

LCD Keypad<br />

The following lists the trouble zones that operate on the LCD keypad module. The LCD keypad<br />

module has 8 trouble zones.<br />

Zone Number Description Type Group<br />

KPxxx:01 Module Tamper System Tamper System<br />

KPxxx:02 Power Trouble Power Fault General<br />

KPxxx:03 Panic * *<br />

KPxxx:04 Duress * *<br />

KPxxx:05 Door Left Open Left Open Access<br />

KPxxx:06 Door Forced Open Forced Door Access<br />

KPxxx:07 Invalid Code Lockout Attempts Access<br />

KPxxx:08 Module Offline Module Offline System<br />

In the above table a '*' indicates that the trouble zone will not generate a system trouble as<br />

by default it is not assigned a trouble type or group. This can be done if required but is not<br />

recommended.<br />

When using the reference table the LCD keypad address should be used in place of the 'xxx'.<br />

Zone Expander<br />

The following lists the trouble zones that operate on the zone expander module. The zone<br />

expander module has 8 trouble zones.<br />

Zone Number Description Type Group<br />

ZXxxx:01 Module Tamper System Tamper System<br />

ZXxxx:02 AC failure Power Fault General<br />

ZXxxx:03 Low Battery Power Fault General<br />

ZXxxx:04 Aux Failure Power Fault General<br />

ZXxxx:05 Bell 1 Cut/Tamper Bell/PGM Fault General<br />