The area or partition that is being reported from 000 to<br />

999.<br />

Event Code<br />

In the example the event code is BA (Burglary Alarm)<br />

however there are a large number of event codes, refer<br />

to the reporting maps for more information.<br />

4 Digit zone or user number that generate the event<br />

code.<br />

There are various options that can be selected to change the method in which the system will<br />

report the message. The size of the account code, zones and user numbers can be changed to<br />

allow more flexible configurations however it is not recommended to change from the<br />

standard configuration.<br />

DVAC (Surgard)<br />

The DVAC reporting format is a hard line communication format used in North America over<br />

the Bell Telecom network. Normal burglar and zone reporting events use the standard zone<br />

reporting codes for alarm, restore, tamper and bypass. Special codes can be assigned to a<br />

zone type when reporting if variations to the codes are required, for an example a<br />

refrigeration alarm can be sent using a special code of 27.<br />

Zones are reported using the standard DVAC burglary codes.<br />

Alarm / Open 09 (BA) Burglary Alarm 89 (BR) Burglary Restore<br />

Tamper 29 (TA) Burglary Tamper A9 (TH) Tamper Restore<br />

Bypass 49 (ZB) Zone Bypass C9 (ZH) Bypass Removed<br />

ModBUS Remote<br />

ModBUS Remote is a highly flexible modem based reporting format that is ideal for large scale<br />

integrated SCADA solutions that connect to a third party ModBUS remote receiver (It is<br />

recommended to use a Protégé System <strong>Controller</strong> in remote ModBUS receive mode).<br />

With the ability to activate specific registers and transfer data according to preset values the<br />

ModBUS remote reporting function is ideal for monitoring wide spread buildings, utility<br />

systems, city property and state wide facilities.<br />

The ModBUS remote service works on the use of the account code as an offset to the specific<br />

point number that must be activated in the remote monitoring system which is usually<br />

connected to display graphic on a SCADA control system such as Citect, WonderWare, The<br />

FIX or DAQ Factory.<br />

By setting an account code for the service and the reporting type in the zone type<br />

configuration the desired point will be activated at the central receiving location that is<br />

operating a Protégé <strong>Controller</strong> in ModBUS receiver mode.<br />