GG<br />

XYZ<br />

S<br />

Group or Partition (Area) number composed using two<br />

hex digits 0-9 and B-F. Use 00 to indicate that no<br />

specific group or partition information is applicable.<br />

Zone Number (Event Reports) or User Number for<br />

(Open / Close Reports) composed using the digits 0-9<br />

and B-F. Use 000 to indicate that no specific zone or<br />

user information applies.<br />

Sum of all digits + S such that a MOD 15 will result in a<br />

0. Not a 0 shall be transmitted as a 10 and valued as a<br />

10 for checksum purposes even though it is displayed<br />

and printed as a '0'.<br />

The Protégé System controller does not change or alter messages from this format when<br />

Contact ID is selected as the reporting format.<br />

SIA L2 (SIA Level Two)<br />

SIA Level Two is a modem based reporting format that is ideal for large scale integrated<br />

solutions such as the Protégé System. Comprising of a multiple message format and tonal<br />

acknowledgement the SIA (Security Industry Association) format provides many reporting<br />

features ideal for access control, automation and large burglary.<br />

The SIA protocol is pre-defined and requires no further programming to operate with the<br />

exception of an account code for an area or service that is running SIA. It is also possible to<br />

assign a special code to the zone type being used for reporting if needed. The custom types<br />

are shown in the table following the zone types assigned to each module.<br />

Zones are reported using the standard burglary codes as detailed below. Openings, closings<br />

and other area operations are reported used the area reporting codes.<br />

Alarm / Open BA BR<br />

Tamper BT BJ<br />

Bypass BB BR<br />

SIA Level 2 Message Format<br />

The format of the SIA messages can vary greatly depending on the leading zero's<br />

configuration for each of the various data code packets that can be sent. Given the large<br />

number of zones, users and areas the Protégé System attempts to use the maximum of these<br />

that is available. Some provision is provided to reduce the size of these fields (Account Code<br />

to 4 Digits, Zone Numbers to 4 Digits) to allow easy integration with monitoring software.<br />

When configuring the automation software at the monitoring station for the information<br />

coming from the receiver the following format should be used. In most cases a 4 digit account<br />

code can be set in the service and used as default.<br />

The first transmitted data is always the account code block, this is not shown and typically<br />

prefixed with a D or F dependent on the size of the account code. This can be either 4 or 6<br />

digits (D# or F#).<br />

N ri GGG BA WXYZ ....<br />

Where:<br />

N<br />

Signifies a new event or an O will signify a old event<br />

that is being reported.<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />

386