Quick Arming/Disarming. Used to report area control<br />

that does not arm with an exit delay.<br />

Key Switch Arming/Disarming. Sent when an area is<br />

armed or disarmed from a Zone or Programmable<br />

Function.<br />

Stay Arming/Disarming. Sent when the area is stay<br />

armed indicating that internal zones (Zones with the<br />

Stay Option set) are not active.<br />

Partial Arming/Disarming. Sent when the area is<br />

armed with zones that are bypassed.<br />

Recent Arming. Sent when the area has armed and an<br />

alarm has activated within the recent closing time.<br />

408<br />

409<br />

441<br />

456<br />

459<br />

SIA Area Reporting Codes<br />

Description<br />

SIA Disarming<br />

Code<br />

Area Arming/Disarming. This is sent with a OP<br />

user ID of 000 and is not normally used.<br />

Area Arming/Disarming By User. This is sent OP<br />

with the user ID that disarmed/armed the<br />

area. This is the standard used for normal<br />

area arming.<br />

Area Group Arming/Disarming By User. When OG<br />

a group of areas are controlled by a user the<br />

group code will be used for each area in the<br />

group.<br />

Automatic Area Arming/Disarming. When the OA<br />

system arms/disarms an area in response to<br />

an event or action the automatic code will be<br />

used and the User ID of 999 will be sent to<br />

show it is a system user.<br />

Cancel Area Arming/Disarming. The cancel OA<br />

arming is used when a deferred area is<br />

stopped from completing the arming cycle,<br />

previously code 405 was used which is now<br />

obsolete.<br />

Early Arming/Disarming. Used to send an OK<br />

early open or close message when the area is<br />

armed before it is due or disarmed before it is<br />

due.<br />

Late Arming/Disarming. Used in the opposite OJ<br />

to the Early the message is sent when it is<br />

not closed before the due time and not<br />

opened before the due time.<br />

Remote Arming/Disarming. Used to report OQ<br />

area control functions that are actioned<br />

remotely to the Protégé System <strong>Controller</strong><br />

(Protégé SMGT, Automation Control or C-Bus<br />

are examples).<br />

Quick Arming/Disarming. Used to report area OP<br />

control that does not arm with an exit delay.<br />

Key Switch Arming/Disarming. Sent when an OS<br />

area is armed or disarmed from a Zone or<br />

Programmable Function.<br />

Stay Arming/Disarming. Sent when the area OP<br />

SIA Arming<br />

Code<br />

CL<br />

CL<br />

CG<br />

CA<br />

CE<br />

CK<br />

OT<br />

CQ<br />

CG<br />

CS<br />

CG<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />