PX001:07 LT LR 7119<br />

PX001:08 YP YQ 7120<br />

PX002:01 YP YQ 7121<br />

| | | | | | |<br />

PX016:08 UA UH 7240<br />

PX017:01 YP YQ 9999<br />

| | | | | | |<br />

PX250:08 UA UH 9999<br />

In the above table a reporting code of 9999 indicates that the trouble zone is outside the<br />

maximum trouble zones that can be reported for the module type.<br />

Analog Input/Output Expander Trouble Zones<br />

The Analog Input and Output Expanders will report trouble zones from 1 to 8 on the first 32<br />

modules, all modules above address AE032 will be reported using the default code of 9999.<br />

Zone Number Alarm Code Restore Code Reporting Point Number<br />

AE001:01 TA TH 7241<br />

AE001:02 AT AR 7242<br />

AE001:03 AT AR 7243<br />

AE001:04 YP YQ 7244<br />

AE001:05 YP YQ 7245<br />

AE001:06 YP YQ 7246<br />

AE001:07 YP YQ 7247<br />

AE001:08 UA UA 7248<br />

AE002:01 TA TH 7249<br />

| | | | | | |<br />

AE032:08 UA UH 7505<br />

AE033:01 YP YQ 9999<br />

| | | | | | |<br />

AE250:08 UA UH 9999<br />

In the above table a reporting code of 9999 indicates that the trouble zone is outside the<br />

maximum trouble zones that can be reported for the module type.<br />

DVAC Surgard Zone<br />

The following tables show the reporting codes for the zones when the DVAC Surgard<br />

Reporting format is used. A DVAC reporting code is the actual code that is transmitted on the<br />

DVAC communication line, this code is more than likely translated by the alarm monitoring<br />

receiving unit in to a SIA or similar reporting code. The associated code is shown in the<br />

following table in brackets to help diagnose DVAC reporting data.<br />

The DVAC communication format is extremely limited in the capacity that it can communicate<br />

and therefore a large number of zones are group on to a maximum zone number when<br />

reported. This limitation is due to the capacity of the DVAC protocol.<br />

Please refer to the section Reporting Codes on page XX for additional information on the<br />

reporting codes used for DVAC. The DVAC protocol closely resembles the SIA formatted data<br />

when transmitted.<br />

Control Panel Zones<br />

The control panel will report all zones from 1 to 16 using any of the available table<br />

configurations.<br />