2 Reader Expander<br />

The 2 reader expander will report trouble zones from 1 to 16 on the first 16 modules, all<br />

modules above address RD002 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

RD001:01 145 (Module Tamper) 677<br />

RD001:02 301 (AC Loss) 678<br />

RD001:03 302 (Low System Battery) 679<br />

RD001:04 312 (Auxiliary Fuse) 680<br />

RD001:05 312 (Lock Trouble) 681<br />

RD001:06 423 (Door 1 Forced) 682<br />

RD001:07 423 (Door 2 Forced) 683<br />

RD001:08 426 (Door 1 Left Open) 684<br />

RD001:09 426 (Door 2 Left Open) 685<br />

RD001:10 312 (Reader 1 Power Supply) 686<br />

RD001:11 312 (Reader 2 Power Supply) 687<br />

RD001:12 145 (Reader 1 Tamper) 688<br />

RD001:13 145 (Reader 2 Tamper) 689<br />

RD001:14 461 (Door 1 Access Attempts) 690<br />

RD001:15 461 (Door 2 Access Attempts) 691<br />

RD001:16 143 (Module Offline) 692<br />

RD002:01 143 (Module Tamper) 693<br />

| | | | | | | |<br />

RD002:16 143 (Module Offline) 932<br />

RD003:01 145 (Module Tamper) 999<br />

| | | | | | | |<br />

RD250:16 143 (Module Offline) 999<br />

In the above table a reporting code of 999 indicates that the trouble zone is outside the<br />

maximum trouble zones that can be reported for the module type.<br />

16 PGM Output Expander<br />

The 16 PGM output expander will report trouble zones from 1 to 8 on the first 2 modules, all<br />

modules above address PX002 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

PX001:01 145 (Module Tamper) 933<br />

PX001:02 301 (AC Loss) 934<br />

PX001:03 302 (Low System Battery) 935<br />

PX001:04 312 (Auxiliary Fuse) 936<br />

PX001:05 140 (General Alarm) 937<br />

PX001:06 140 (General Alarm) 938<br />

PX001:07 140 (General Alarm) 939<br />

PX001:08 143 (Module Offline) 940<br />

PX001:01 143 (Module Tamper) 941<br />

| | | | | | | |<br />

PX002:08 143 (Module Offline) 964<br />

PX002:01 145 (Module Tamper) 999<br />

| | | | | | | |<br />

PX250:16 143 (Module Offline) 999<br />

In the above table a reporting code of 999 indicates that the trouble zone is outside the<br />

maximum trouble zones that can be reported for the module type.<br />