Please refer to the section Reporting Codes on page XX for additional information on the<br />

reporting codes used for Contact ID.<br />

Control Panel Zones<br />

The control panel will report all zones from 1 to 16 using any of the available table<br />

configurations.<br />

Zone Number Contact ID Code Reporting Point Number<br />

CP001:01 130 (Burglary) 001<br />

CP001:02 130 (Burglary) 002<br />

CP001:03 130 (Burglary) 003<br />

CP001:04 130 (Burglary) 004<br />

CP001:05 130 (Burglary) 005<br />

CP001:06 130 (Burglary) 006<br />

CP001:07 130 (Burglary) 007<br />

CP001:08 130 (Burglary) 008<br />

CP001:09 130 (Burglary) 009<br />

CP001:10 130 (Burglary) 010<br />

CP001:11 130 (Burglary) 011<br />

CP001:12 130 (Burglary) 012<br />

CP001:13 130 (Burglary) 013<br />

CP001:14 130 (Burglary) 014<br />

CP001:15 130 (Burglary) 015<br />

CP001:16 130 (Burglary) 016<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum<br />

zones that can be reported in some cases the zone number will reflect the module address<br />

that the zone was activated from to aid in service.<br />

Keypad Zones<br />

The keypad will report zones from 1 to 4 on the first 2 modules, all modules above address<br />

KP006 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

KP001:01 130 (Burglary) 017<br />

KP001:02 130 (Burglary) 018<br />

KP001:03 130 (Burglary) 019<br />

KP001:04 130 (Burglary) 020<br />

KP002:01 130 (Burglary) 021<br />

KP002:02 130 (Burglary) 022<br />

| | | | | | | |<br />

KP002:04 130 (Burglary) 040<br />

KP003:01 130 (Burglary) 999<br />

| | | | | | | |<br />

KP250:04 130 (Burglary) 999<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum<br />

zones that can be reported for the module type.<br />

16 Zone Expander<br />

The 16 zone expander will report zones from 1 to 16 on the first 20 modules, all modules<br />

above address ZX004 will be reported using the default code of 999.<br />