CP001:15 330 (Expansion Card Problem) 515<br />

CP001:16 330 (COM Port 1 Problem) 516<br />

CP001:17 330 (COM Port 2 Problem) 517<br />

CP001:18 330 (COM Port 3 Problem) 518<br />

CP001:19 330 (COM Port 4 Problem) 519<br />

CP001:20 330 (Ethernet Link Failure) 520<br />

CP001:21 331 (DVAC Failure To Poll) 521<br />

CP001:22 331 (ModBUS Failure To Poll) 522<br />

CP001:23 416 (Remote Interface Login) 523<br />

CP001:24 466 (Installer Login UN00002) 524<br />

CP001:25 415 (Service 1 Stopped) 525<br />

CP001:26 415 (Service 2 Stopped) 526<br />

CP001:27 415 (Service 3 Stopped) 527<br />

CP001:28 415 (Service 4 Stopped) 528<br />

CP001:29 140 (General Alarm) 529<br />

| | | | | | | | | | |<br />

CP001:64 140 (General Alarm) 564<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum<br />

zones that can be reported in some cases the zone number will reflect the module address<br />

that the zone was activated from to aid in service.<br />

Keypad Zones<br />

The keypad will report trouble zones from 1 to 8 on the first 6 modules, all modules above<br />

address KP006 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

KP001:01 145 (Module Tamper) 565<br />

KP001:02 302 (Low Voltage) 566<br />

KP001:03 120 (Panic 1+3) 567<br />

KP001:04 121 (Duress Code) 568<br />

KP001:05 423 (Forced Access) 569<br />

KP001:06 426 (Door Open) 570<br />

KP001:07 461 (Invalid Code Lockout) 571<br />

KP001:08 143 (Module Offline) 572<br />

KP002:01 145 (Module Tamper) 573<br />

KP002:02 302 (Low Voltage) 574<br />

| | | | | | | |<br />

KP006:08 143 (Module Offline) 612<br />

KP007:01 145 (Module Tamper) 999<br />

| | | | | | | |<br />

KP250:04 143 (Module Offline) 999<br />

In the above table a reporting code of 999 indicates that the zone is outside the maximum<br />

zones that can be reported for the module type.<br />

16 Zone Expander<br />

The 16 zone expander will report trouble zones from 1 to 16 on the first 4 modules, all<br />

modules above address ZX004 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

ZX001:01 145 (Module Tamper) 613<br />

ZX001:02 301 (AC Loss) 614<br />

ZX001:03 302 (Low System Battery) 615<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />