BYPASS<br />

Introduction<br />

To access the bypass menu, login using a valid code that is allowed bypass menu access and<br />

then select [MENU, 7]. You can then browse the bypass menu and select the bypass that you<br />

want to perform on your Protégé System.<br />

Bypass Menu<br />

The bypass menu consists of 2 entries that can be scrolled to using the [] and [] arrow or<br />

selected directly using the shortcut keys shown in the figure below.<br />

MENU 7<br />

ZONE<br />

BYPASSING<br />

MENU 7, 1<br />

BYPASS ZONE<br />

MENU 7, 2<br />

BYPASS<br />

TROUBLE ZONE<br />

Bypassing Zones<br />

Figure 17 - Zone Bypassing Menu Overview<br />

To bypass zones select [MENU, 7, 1] then using the [] and [] arrows to scroll the<br />

available zones. A zone can be bypassed by pressing the [1] key to bypass the zone and then<br />

the [2] key to remove the zone bypass. A zone can also be bypassed in latch mode by<br />

pressing the [3] key. If a zone is bypassed normally [1] the zone bypass will be removed the<br />

next time the area disarms, please not all areas that have this zone programmed must disarm<br />

for the bypass to be removed.<br />

• Select the bypass zone menu [MENU, 7, 1]. The display will show the first zone in<br />

the system.<br />

Warehouse PIR<br />

is not BYPASSED<br />

• If a normal bypass is required press the [1] key the zone will then toggle state and<br />

the display will show the bypassed message below.<br />

Warehouse PIR<br />

is BYPASSED<br />

355 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>