Custom Reader Format<br />

The Protege System <strong>Controller</strong> and Protege Reader Expansion Modules can support custom<br />

Wiegand Card Reader formats for the times when the format required is not one of the many<br />

available preset formats.<br />

One custom format can be added per controller and used by any reader expander in the<br />

system.<br />

Interface Type<br />

To access the custom reader format programming login using a valid installer code and then<br />

select [MENU, 4, 9, 5]. The screen displays the first entry to modify as there is only one<br />

panel no record selection is required. The first item that is programmable is the output<br />

format.<br />

The data can either be output as Wiegand (D0 and D1) or Magnetic Data (Clock and Data).<br />

CF001 Type<br />

Wiegand<br />

Use the [1] and [3] keys to scroll the format type until you reach the required format and<br />

press [ENTER] to proceed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Data Length<br />

The data length defines the total number of bits that are sent by the card reader for each card<br />

badge.<br />

CF001 Length<br />

bits: 026<br />

To modify the length (000 to 255), use the keypad as explained in section Entering Decimal<br />

Numbers on Page 405 and press [ENTER].<br />

Facility Code Start<br />

The facility code start defines the index where the facility code data starts in the data<br />

transmitted. The count starts at zero.<br />

CF001 Site Start<br />

bits: 001<br />

To modify this parameter (000 to 255), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER].<br />

Facility Code End<br />

The facility code end defines the index where the facility code data ends in the data<br />

transmitted. The count starts at zero.<br />

333 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>