Option 4, 5, 6, 7 and 8 - Reserved<br />

Reserved Do Not Modify.<br />

Reserved Do Not Modify.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Test Report Time<br />

The test report time in conjunction with option 2 sets the time of the day or the period that<br />

the test report trouble zone activates. When option 2 is disabled the time programmed will be<br />

used as a period between reports in hours and minutes.<br />

Test report<br />

time: 02:00<br />

To modify the test report time (00:00 to --:--), use the keypad as explained in the section<br />

Entering Time and Date Values on Page 405 and press [ENTER]. Setting a test report time of<br />

--:-- will disable the activation of a test report.<br />

Automatic Offline User Update Time<br />

The automatic user offline update time in conjunction with option 1 in the miscellaneous<br />

options allows the panel to update the users and other offline parameters on all intelligent<br />

modules at a set time of the day.<br />

Offline update<br />

time: 03:00<br />

To modify the offline update time (00:00 to --:--), use the keypad as explained in the section<br />

Entering Time and Date Values on Page 405 and press [ENTER]. Setting an offline update<br />

time of --:-- will disable the offline user update function.<br />

Modem Country Selection<br />

The onboard modem must be configured for the region that the System <strong>Controller</strong> is being<br />

installed in to ensure proper operation.<br />

Modem Country<br />

NZ/Aus<br />

Use the [1] and [3] keys to scroll the modem country selection until you reach the required<br />

country and press [ENTER] to proceed. For more information about the list control data<br />

entry refer to the section List Control Data Entry on Page 406.<br />

Default Panel Language<br />

The System <strong>Controller</strong> supports multiple languages on the Keypad and the Serial Event<br />

Printers. The language selected here will be the default language for users who have no<br />

language selected and also for any events.<br />

331 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>