01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Automation to<br />

modify: AT001<br />

Type the appropriate 3-digit automation number or use the [] and [] keys to scroll the<br />

available automation entries. When the desired automation number appears on the screen,<br />

press [ENTER] to program the selected automation entry. The maximum number of<br />

automation outputs that can be programmed is limited by your system’s memory and<br />

configured profile.<br />

Automation Name<br />

If the selected automation entry has a name associated (some automation entries may not<br />

have a name associated with them) the name programming screen will be shown.<br />

AT001 Name<br />

*Automation 001<br />

To scroll automation entries by name use the [] and [] keys. To modify or enter a new<br />

name for the selected automation item use the keypad as explained in section Entering Text<br />

and Names on Page 406 and press [ENTER].<br />

By default the automation name will be prefixed by an '*' this indicates that the name is an<br />

editable name in the system.<br />

Automation PGM<br />

The automation entry will control the PGM or PGM group that is assigned to the control PGM<br />

option.<br />

AT001 Control<br />

pgm: --000:00<br />

To modify the automation PGM or PGM Group, use the settings as explained in section<br />

Entering PGM and PGM Groups on Page 410.<br />

Automation PGM Activation Time<br />

You can override the programmed activation time for a PGM or the group of PGM's by setting<br />

an activation time.<br />

AT001 PGM on<br />

time: 00000 secs<br />

To modify the PGM on time (00000 to 65535 Seconds), use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER].<br />

Automation Clipsal C-Bus Application Number<br />

The Clipsal C-Bus application number is used to link this automation point to a C-Bus<br />

Application that is communicating with the system controller via a <strong>PRT</strong>-COMM and Serial<br />

Communications Interface. For example if you want to link this automation point to activate<br />

when a Lighting, Switching and Load Control application command is generated for a<br />

particular Group Address set the Application Type to 056 (056 or $38 Hex is the Lighting,<br />

321 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>