door control function. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Use the [1] and [3] keys to scroll the door control mode until you reach the setting that you<br />

want to use and then press [ENTER] to proceed to the next programmable option for the<br />

door control function. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Door Mode<br />

Menu Timed<br />

Menu Latched<br />

Description<br />

The Floor Group will be unlocked for the token time that is<br />

programmed for the programmable function. Use this mode when<br />

you want to unlock the door for defined time. The floors will lock<br />

after the token time has expired.<br />

The floors will be latched in the unlocked state and will remain<br />

unlocked until controlled from:<br />

• A LCD Keypad<br />

• Protégé System Management Suite<br />

• Scheduled Action<br />

• Area Status<br />

• A Programmable function.<br />

Fire Control<br />

The door will be latched in the fire control unlock state and will<br />

remain unlocked until controlled from:<br />

• A LCD Keypad<br />

• Protégé System Management Suite<br />

• A Programmable function that is programmed to deactivate<br />

the fire alarm control.<br />

Register Counter<br />

To program the register counter function ensure that the function you have selected is halted.<br />

Select the function type selection screen as shown below for Register Counter.<br />

FN001 Func Type<br />

Reg Counter<br />

Use the [1] and [3] keys to scroll the function types until you reach the door control selection<br />

and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the door control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />

317 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>