door every 30 seconds.<br />

Not Follow and<br />

Test<br />

Performs the same function as above however the output is<br />

inverted (NOT). This logic action is a test action, consult the<br />

follow and test action for an explanation of the Test Function.<br />

Input One<br />

ON<br />

OFF<br />

Output<br />

LOCKED<br />

UNLOCKED<br />

Pulse On<br />

The pulse on action will unlock the floor group only when the<br />

input one has transitioned from an off to an on state. The floor<br />

group will not be modified further from this state and will not be<br />

modified if it is turned OFF by another function.<br />

Input One<br />

Output<br />

UNLOCKED<br />

Not Pulse On<br />

The not pulse on action will lock the door only when the input one<br />

has transitioned from an off to an on state. The door will not be<br />

modified further from this state and will not be modified if it is<br />

turned ON by another function.<br />

Input One<br />

Output<br />

LOCKED<br />

Pulse Off<br />

The pulse on action will unlock the floor group only when the<br />

input one has transitioned from an ON to an OFF state. The floor<br />

group will not be modified further from this state and will not be<br />

modified if it is turned OFF by another function.<br />

Input One<br />

Output<br />

UNLOCKED<br />

Not Pulse Off<br />

The not pulse off action will unlock the floor group only when the<br />

input one has transitioned from an ON to an OFF state. The<br />

output will not be modified further from this state and will not be<br />

modified if it is turned ON by another function.<br />

Input One<br />

Output<br />

LOCKED<br />

Input One PGM<br />

Input one selects the input source to the elevator control process that is being configured.<br />

Input one must be programmed with a valid input source, if an input source is selected that is<br />

not valid when the function is started an error will be generated and the function suspended.<br />

An input source can be a PGM (Programmable Output).<br />