FN001 Func Type<br />

Elevator Ctrl<br />

Use the [1] and [3] keys to scroll the function types until you reach the door control selection<br />

and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the elevator control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to proceed to the next programmable option for the elevator control function.<br />

For more information about the list control data entry refer to the section List Control Data<br />

Entry on Page 406.<br />

Elevator Action<br />

The action determines what action is performed on the elevator group that is programmed as<br />

a result of the Input PGM. An action MUST be selected for the programmable function to<br />

operate correctly.<br />

FN001 Action<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the required action that<br />

you want to be performed and then press [ENTER] to proceed to the next programmable<br />

option for the eleavtor control function. For more information about the list control data entry<br />

refer to the section List Control Data Entry on Page 406.<br />

Logic Action<br />

Follow and Test<br />

Description<br />

The floor group status follows the programmed input one state<br />

and will retest the input state every 30 second interval and<br />

change the floor group state accordingly.<br />

Input One<br />

ON<br />

OFF<br />

Floor Group<br />

UNLOCKED<br />

LOCKED<br />

Test Action - If the floor group state is changed externally or is<br />

part of another programmable function the programmable<br />

function will only restore the output state after 30 seconds has<br />

elapsed. This time is only used if the programmable function was<br />

NOT responsible for the change in state. If a door has a door<br />

unlock time and the door mode is set to timed this will unlock the<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />