To modify the pre alarm PGM or PGM Group, use the settings as explained in section Entering<br />

PGM and PGM Groups on Page 410<br />

Virtual Door Miscellaneous Options<br />

These options are for the virtual door.<br />

Option 1 – Alarm on Door Left Open<br />

The Alarm PGM will be activated when the door is left open beyond the Max<br />

Open time.<br />

The Alarm PGM is not activated.<br />

Option 2 – Pulse Left Open Alarm<br />

The Alarm PGM will be activated with a pulse time on and off.<br />

The Alarm PGM will be turned on normally.<br />

Option 3 – Alarm on Door Forced<br />

The Alarm PGM will be activated when the door is forced open.<br />

The Alarm PGM is not activated.<br />

Option 4 – Pulse Forced Door Alarm<br />

The Alarm PGM will be activated with a pulse time on and off.<br />

The Alarm PGM will be turned on normally.<br />

Option 5 – Log Left Open Zone Event<br />

Enabled the zone events when the door is left open.<br />

Disables the zone events from being generated.<br />

Option 6 – Log Forced Zone Event<br />

Enabled the zone events when the door is forced open.<br />

Disables the zone events from being generated.<br />

Option 7 and 8 - Reserved<br />

Zone Follows PGM Function<br />

To program the zone follows pgm function ensure that the function you have selected is<br />

halted. Select the function type selection screen as shown below for Zone Control.<br />

FN001 Func Type<br />

Zone Control<br />

Use the [1] and [3] keys to scroll the function types until you reach the door control selection<br />

and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the door control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />