When the door closes, the zone will also close. Place this zone in a reportable area to enabled<br />

reportable events from the virtual door.<br />

FN001 Forced<br />

Zone CP001:01<br />

To modify the input Zone, use the settings as explained in section Entering Zones on Page<br />

411.<br />

Virtual Door Unlock Time<br />

The unlock time determines how long the lock that controls the virtual door will remain<br />

unlocked for when a user access's the door.<br />

FN001 Unlock<br />

time: 005 secs<br />

To modify the unlock time (000 to 255 Seconds), use the keypad as explained in section<br />

Entering Decimal Numbers on Page 405 and press [ENTER]. Setting a 000 value will result in<br />

the door not unlocking when a users access's the door.<br />

Virtual Door Maximum Open Time<br />

The maximum open time is programmed to allow the door to be left open for a certain period<br />

before it will generate a door left open condition. When the left open condition is reached this<br />

will activate the alarm PGM and open the left open zone.<br />

DR001 Pre-Alarm<br />

time: 030 secs<br />

To modify the pre-alarm time (000 to 255 Seconds), use the keypad as explained in section<br />

Entering Decimal Numbers on Page 405 and press [ENTER]. Setting a 000 value will result in<br />

the pre-alarm feature not operating.<br />

Virtual Door Lock PGM or PGM Group<br />

You can assign a PGM or PGM group that controls the physical electric lock for the door.<br />

FN001 Door Lock<br />

pgm: --000:00<br />

To modify the door lock PGM or PGM Group, use the settings as explained in section Entering<br />

PGM and PGM Groups on Page 410.<br />

Alarm PGM or PGM Group<br />

You can assign a PGM or PGM group that will activate when the door goes into either a left<br />

open or forced condition. Use this to warn the user to close the door. See miscellaneous<br />

options below for configuring how the PGM is activated.<br />