off if the function is operating in a Test and Follow mode.<br />

Lockdown<br />

(Entry Allowed)<br />

Lockdown (Exit<br />

Allowed)<br />

Lockdown<br />

(Entry and Exit<br />

Allowed)<br />

Door Lockdown with Entry Allowed will be started for the door or<br />

door group and will remain locked down until it is cancelled from<br />

the Protégé System Management Suite, an LCD Keypad or when<br />

the PGM input goes off if the function is operating in a Test and<br />

Follow mode.<br />

Door Lockdown with Exit Allowed will be started for the door or<br />

door group and will remain locked down until it is cancelled from<br />

the Protégé System Management Suite, an LCD Keypad or when<br />

the PGM input goes off if the function is operating in a Test and<br />

Follow mode.<br />

Door Lockdown with Entry and Exit Allowed will be started for the<br />

door or door group and will remain locked down until it is<br />

cancelled from the Protégé System Management Suite, an LCD<br />

Keypad or when the PGM input goes off if the function is<br />

operating in a Test and Follow mode.<br />

Virtual Door Function<br />

To program the virtual door function ensure that the function you have selected is halted.<br />

Select the function type selection screen as shown below for the Virtual Door.<br />

FN001 Func Type<br />

Virtual Door<br />

Use the [1] and [3] keys to scroll the function types until you reach the door control selection<br />

and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the door control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to proceed to the next programmable option for the door control function. For<br />

more information about the list control data entry refer to the section List Control Data Entry<br />

on Page 406.<br />

309 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>