Control Door Group<br />

The control door group selects the area group to control as a result of the action being<br />

performed by the programmable function. To control a door leave the control door group set<br />

at none and program a door in the control door section. Programming a door and a door<br />

group will result in the door group not being used.<br />

FN001 Door Grp<br />

None<br />

Use the [1] and [3] keys to scroll the door groups until you reach the required group and<br />

then press [ENTER] to proceed to the next programmable option for the door control<br />

function. For more information about the list control data entry refer to the section List<br />

Control Data Entry on Page 406.<br />

Door Control Mode<br />

The control mode selects how the door will be controlled in the control door or control door<br />

group setting. This allows a door to be unlocked for the door unlock time, unlock latched or<br />

unlocked in the fire alarm mode.<br />

FN001 Door Mode<br />

Menu Timed<br />

Use the [1] and [3] keys to scroll the door control mode until you reach the setting that you<br />

want to use and then press [ENTER] to proceed to the next programmable option for the<br />

door control function. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Door Mode<br />

Menu Timed<br />

Menu Latched<br />

Description<br />

The Door will be unlocked for the door unlock time that is<br />

programmed for the door. Use this mode when you want to<br />

unlock the door for unlock time. The door will lock after the<br />

unlock time has expired.<br />

The door will be latched in the unlocked state and will remain<br />

unlocked until controlled from:<br />

• A LCD Keypad<br />

• Protégé System Management Suite<br />

• Scheduled Action<br />

• Area Status<br />

• A Programmable function.<br />

Fire Control<br />

The door will be latched in the fire control unlock state and will<br />

remain unlocked until controlled from:<br />

• A LCD Keypad<br />

• Protégé System Management Suite<br />

• A Programmable function that is programmed to deactivate<br />

the fire alarm control.<br />

Lockdown<br />

Door Lockdown will be started for the door or door group and will<br />

remain locked down until it is cancelled from the Protégé System<br />

Management Suite, an LCD Keypad or when the PGM input goes<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />