modified further from this state and will not be modified if it is<br />

turned ON by another function.<br />

Input One<br />

Output<br />

LOCKED<br />

Pulse Off<br />

The pulse on action will unlock the door only when the input one<br />

has transitioned from an ON to an OFF state. The door will not be<br />

modified further from this state and will not be modified if it is<br />

turned OFF by another function.<br />

Input One<br />

Output<br />

UNLOCKED<br />

Not Pulse Off<br />

The not pulse off action will unlock the door only when the input<br />

one has transitioned from an ON to an OFF state. The output will<br />

not be modified further from this state and will not be modified if<br />

it is turned ON by another function.<br />

Input One<br />

Output<br />

LOCKED<br />

Input One PGM<br />

Input one selects the input source to the door control process that is being configured. All<br />

door control functions use at least one input source. Input one must be programmed with a<br />

valid input source, if an input source is selected that is not valid when the function is started<br />

an error will be generated and the function suspended. An input source can be a PGM<br />

(Programmable Output).<br />

FN001 Input one<br />

pgm: --000:00<br />

To modify the input PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

Control Door<br />

The control door selects the door to control as a result of the action being performed by the<br />

programmable function. To control a door group leave the control door option set to none and<br />

proceed to the Control Door Group entry screen. Selecting both a door and a door group will<br />

result in only the door being controlled and the door group being ignored.<br />

FN001 Door<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the door that you want to<br />

control and then press [ENTER] to proceed to the next programmable option for the door<br />

control function. For more information about the list control data entry refer to the section<br />

List Control Data Entry on Page 406.<br />