Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to proceed to the next programmable option for the door control function. For<br />

more information about the list control data entry refer to the section List Control Data Entry<br />

on Page 406.<br />

Door Action<br />

The action determines what action is performed on the door or door group that is<br />

programmed as a result of the Input PGM. An action MUST be selected for the programmable<br />

function to operate correctly.<br />

FN001 Action<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the required action that<br />

you want to be performed and then press [ENTER] to proceed to the next programmable<br />

option for the door control function. For more information about the list control data entry<br />

refer to the section List Control Data Entry on Page 406.<br />

Logic Action<br />

Follow and Test<br />

Description<br />

The door status follows the programmed input one state and will<br />

retest the input state every 30 second interval and change the<br />

door state accordingly.<br />

Input One<br />

ON<br />

OFF<br />

Door<br />

UNLOCKED<br />

LOCKED<br />

Test Action - If the door state is changed externally or is part of<br />

another programmable function the programmable function will<br />

only restore the output state after 30 seconds has elapsed. This<br />

time is only used if the programmable function was NOT<br />

responsible for the change in state. If a door has a door unlock<br />

time and the door mode is set to timed this will unlock the door<br />

every 30 seconds.<br />

Not Follow and<br />

Test<br />

Performs the same function as above however the output is<br />

inverted (NOT). This logic action is a test action, consult the<br />

follow and test action for an explanation of the Test Function.<br />

Input One<br />

ON<br />

OFF<br />

Output<br />

LOCKED<br />

UNLOCKED<br />

Pulse On<br />

The pulse on action will unlock the door only when the input one<br />

has transitioned from an off to an on state. The door will not be<br />

modified further from this state and will not be modified if it is<br />

turned OFF by another function.<br />

Input One<br />

Output<br />

UNLOCKED<br />

Not Pulse On<br />

The not pulse on action will lock the door only when the input one<br />

has transitioned from an off to an on state. The door will not be<br />