Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />

Setting the run once option for the ripple PGM function will result in NO operation<br />

being performed and the function stopping a short time after it is started.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to move to the next programmable option for the ripple PGM function. For<br />

more information about the list control data entry refer to the section List Control Data Entry<br />

on Page 406.<br />

Enabled Control PGM<br />

The Enabled Control PGM is used to operate the ripple PGM function in the STEP UP mode<br />

when it is activated and it will run in the STEP DOWN mode when the Enable PGM is<br />

deactivated. If no enabled PGM is set the function will never run the ripple stages.<br />

FN001 Enabled<br />

pgm: --000:00<br />

To modify the enabled PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410. To select a data register press the stay key, the following screen will be<br />

shown and a memory register location can be selected. To view the memory register locations<br />

refer to appendix memory registers on page XX.<br />

Ripple On Time<br />

The ripple on time determines the time that each PGM output will be delayed before being<br />

activated when the ripple control function is stepping the PGM outputs up.<br />

FN001 Ripple on<br />

time: 00000 secs<br />

To modify the ripple on time (00000 to 65535 seconds), use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER].<br />

Ripple Off Time<br />

The ripple off time determines the time that each PGM output will be delayed before being<br />

deactivated when the ripple control function is stepping the PGM outputs down.<br />

FN001 Ripple off<br />

time: 00000 secs<br />

To modify the ripple off time (00000 to 65535 seconds), use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER].<br />

303 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>