FN001 Fresh temp<br />

reg: 00000<br />

To modify the fresh temperature register (00000 to 65535, use the keypad as explained in<br />

section Entering Decimal Numbers on Page 405 and press [ENTER].<br />

Economiser Damper Register<br />

The Base data register is used as the first register in the list of registers used to configure,<br />

program and control the RTHP. The only registers that are not included in the base registers<br />

are ones that must link to an analog input or analog output for external sensors (Temp,<br />

Humidity or Dampers). A base data register setting MUST be set.<br />

FN001 Space rh<br />

reg: 00000<br />

To modify the base data register (00000 to 65535, use the keypad as explained in section<br />

Entering Decimal Numbers on Page 405 and press [ENTER].<br />

Floor Tempering Control Function<br />

The Floor Tempering programmable function allows the direct control of a single stage floor<br />

tempering system that controls a duct mounted heater and/or cooling compressor. The<br />

support for one heating and one cooling state is provided as well as a forward and reverse<br />

operation.<br />

FN001 Func Type<br />

Floor Temping<br />

Use the [1] and [3] keys to scroll the function types until you reach the Floor Temping<br />

selection and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the Floor Temping control function. For more information about the<br />

list control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator. Setting the run once option for<br />

the RTHP will result in NO operation being performed and the function stopping a short time<br />

after it is started.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to proceed to the next programmable option for the floor temping function.<br />

For more information about the list control data entry refer to the section List Control Data<br />

Entry on Page 406.<br />