Input One<br />

Area Control<br />

DISARM<br />

Input One PGM<br />

Input one selects the input source to the area control process that is being configured. All<br />

area control functions use at least one input source. Input one must be programmed with a<br />

valid input source, if an input source is selected that is not valid when the function is started<br />

an error will be generated and the function suspended. An input source can be a PGM<br />

(Programmable Output) or a Memory Register (Special area of memory that can be used<br />

store values and monitor internal system functions).<br />

FN001 Input one<br />

pgm: --000:00<br />

To modify the input PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

Control Area<br />

The control area selects the area to control as a result of the action being performed by the<br />

programmable function. To control an area group leave the control area option set to none<br />

and proceed to the Control Area Group. Selecting both an area and an area group will result<br />

in only the area being controlled and the area group being ignored. Programming an area and<br />

an area group will result in the area group not being used.<br />

FN001 Area<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the required action that<br />

you want to be performed and then press [ENTER] to proceed to the next programmable<br />

option for the area control function. For more information about the list control data entry<br />

refer to the section List Control Data Entry on Page 406.<br />

Control Area Group<br />

The control area group selects the area group to control as a result of the action being<br />

performed by the programmable function. To control an area leave the control area group<br />

section set to none and program an area in the control area section. Programming an area<br />

and an area group will result in the area group not being used.<br />

FN001 Area Grp<br />

None<br />

Use the [1] and [3] keys to scroll the area groups until you reach the required group and<br />

then press [ENTER] to proceed to the next programmable option for the area control<br />

function. For more information about the list control data entry refer to the section List<br />

Control Data Entry on Page 406.<br />

RTHP Control Function<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />