Output PGM / Memory Register<br />

Output PGM selects the PGM output to activate or deactivate as a result of the action being<br />

performed by the logic process.<br />

FN001 Output<br />

pgm: --000:00<br />

To modify the output PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

Area Control Function<br />

To program the area control function ensure that the function you have selected is halted.<br />

Select the function type selection screen as shown below for Area Control.<br />

FN001 Func Type<br />

Area Control<br />

Use the [1] and [3] keys to scroll the function types until you reach the area control selection<br />

and press [ENTER] to select the function type displayed and proceed to the next<br />

programmable option for the area control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406.<br />

Function Mode<br />

The function mode determines how this function operates with the system controller. By<br />

default a function is set to normal operation. Normal operation will mean the function is<br />

started if it was running when the system restarts or is completely powered down (AC Failure<br />

and Battery Failure). The Run Once mode of operation will allow the function to run once and<br />

then wait to be stopped and started by the user or operator.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and<br />

press [ENTER] to proceed to the next programmable option for the area control function. For<br />

more information about the list control data entry refer to the section List Control Data Entry<br />

on Page 406.<br />

Area Action<br />

The action determines what action is performed on the area or area group that is<br />

programmed as a result of the Input PGM. For key switch arming or simple arming of an area<br />

from a zone input use the area control options in the zone type configuration. Refer to the<br />

Zone Type Programming on Page XX.<br />

FN001 Action<br />

None<br />

Use the [1] and [3] keys to scroll the action types until you reach the required action that<br />

you want to be performed and then press [ENTER] to proceed to the next programmable<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />