state and press the [5] key to cancel the door lockdown. Press the [] to return to the Door<br />

selection display.<br />

The display will show the door input states listed below.<br />

CLOSED<br />

OPEN<br />

FORCED<br />

PREALM<br />

LEFTOP<br />

Door is closed.<br />

Door is open.<br />

Door is forced open.<br />

Door is in a pre-alarm open condition.<br />

Door has been left open.<br />

The display will show the door lock states listed below.<br />

LOCKED<br />

ACCESS<br />

SCHED<br />

TIMED<br />

LATCH<br />

ENTRY<br />

EXIT<br />

MENU<br />

AREA<br />

FIRE<br />

LD-ALL<br />

LD-ENT<br />

LD-EXT<br />

LD-E+E<br />

Lock PGM is deactivated.<br />

Lock PGM is activated by a user entry.<br />

Lock PGM is activated by schedule.<br />

Lock PGM is activated for time period by manual control.<br />

Lock PGM is activated latched by manual control.<br />

Lock PGM is activated request to enter.<br />

Lock PGM is activated request to exit.<br />

Lock PGM is activated keypad control.<br />

Lock PGM is activated by area.<br />

Lock PGM is activated by fire control programmable function.<br />

Door is in Lockdown and will only unlock for a super user.<br />

Door is in Lockdown with Entry Allowed.<br />

Door is in Lockdown with Exit Allowed.<br />

Door is in Lockdown with Entry and Exit Allowed.<br />

Profile Configuration<br />

Profiles configure the local onboard and expanded memory (if it is present) with the number<br />

of supported records (Users, Events, Doors ...). To enter the profile menu select [MENU, 4,<br />

8, 3] you can then scroll the menu for the available options.<br />

Changing Profiles<br />

To change profiles login using a valid installer code and then select [MENU, 4, 8, 3, 1]. The<br />

screen displays “Select profile" as shown in the following example.<br />

Select profile <br />

Standard<br />

Eight profiles are provided that allow the configuration of numerous record structures and<br />

setups, it is also possible to customize the number of records that the controller will function<br />

with by selecting the custom profile.<br />

Use the [1] and [3] keys to scroll the available profiles. When the desired profile is displayed<br />

on the screen, press [ENTER] to load the selected profile. For more information about the list<br />

control data entry refer to the section List Control Data Entry on Page 406. To view a profiles<br />

size and structures select [MENU, 4, 8, 3, 2].<br />

When selecting a Profile a warning screen will be displayed informing the user that the option<br />

will reset the panel and that they need to upload the information to be able to preserve the<br />

information from one profile to the next.<br />