Select zone to<br />

view: CP001:01<br />

Type the appropriate module type, module address and zone number or use the [] and []<br />

keys to scroll the available zones. When the desired zone number appears on the screen,<br />

press [ENTER] to view the selected zone number.<br />

When selecting a Zone the zone address is entered using the Module Type, Module Address<br />

and the number of the zone, this is called Protégé Object Notation.<br />

Information on the Protégé Object Notation and how it applies to programmable objects<br />

within the Protégé System refer to the Object Notation Section on Page 402.<br />

Zone Status Display<br />

When the zone is selected the name of the zone will be displayed on the top line and the state<br />

of the zone will be shown on the bottom line.<br />

Warehouse PIR<br />

is TAMPERED<br />

Use the [] and [] keys to scroll the available zones while in the view screen or press the<br />

[] to return to the zone selection. Pressing the [ARM] key will toggle the display between<br />

the name and the zone identification. Each zone is assigned a unique identification that uses<br />

the Protégé Notation.<br />

CP001:01 Zone<br />

is TAMPERED<br />

The display will show the zone state and will depend on the resistor configuration option<br />

programmed for the zone that is being viewed. The possible states that can be displayed are;<br />

OPEN<br />

CLOSED<br />

SHORT<br />

TAMPERED<br />

Zone is opened.<br />

Zone is closed.<br />

Zone is shorted out or a wiring fault has occurred.<br />

Zone wiring is cut or faulty.<br />

By default the zone name will be shown on the top line of the screen however if no name is<br />

programmed or the name is blank it may be desirable to view the device and address of the<br />

module that the zone is connected to. To view the input in the system it is connected on press<br />

the [ARM] key, the [ARM] key can be pressed repeatedly to toggle between the two display<br />

options.<br />

Viewing Trouble Zones<br />

To access the trouble zone view menu login using a valid installer code and then select<br />

[MENU, 4, 8, 2, 1, 2]. The screen displays “Trouble zone to view” as shown in the following<br />

example.<br />

Trouble zone to<br />

view: CP001:01<br />

Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong><br />