Enabled the service will use the remote buffer for the look up of register<br />

values. This is used when the Protégé System <strong>Controller</strong> is used to receive<br />

alarms and messages from remote sites that communicate in the Remote<br />

ModBUS protocols.<br />

Disabled the service will use the local objects (Areas, Doors and Zones to<br />

send status and information.<br />

Option 6 – Remote Zone Write<br />

Enabled the service will allow specific coil address’s to interact with the<br />

zones on the system. The zones start on the first zone expander. This<br />

setting allows remote SCADA applications to activate alarms in the Protégé<br />

System <strong>Controller</strong> and report these messages to a standard alarm<br />

monitoring station.<br />

Disabled the coil address’s will operate there designated device.<br />

Option 7 and 8 - Reserved<br />

Reserved.<br />

Reserved.<br />

It is recommended not to enable/disable or modify the settings of reserved options.<br />

Fail To Poll Time<br />

The fail to poll time allows a timer to be triggered on each successful poll from the ModBUS<br />

Master. When this timer expires the Fail To Poll PGM output will also be activated.<br />

SV001 Poll fail<br />

time: 120 secs<br />

To modify the poll fail time (000 to 255, a setting of 000 will result in the default of 120<br />

seconds being used), use the keypad as explained in section Entering Decimal Numbers on<br />

Page 405 and press [ENTER].<br />

Fail To Poll PGM Output<br />

The fail to poll PGM output is activated when the ModBUS service poll fail timer expires and is<br />

deactivated when the ModBUS service completes a valid communication. This PGM setting can<br />

be used to trigger an audible alarm or other indication that ModBUS communication has failed<br />

to operate.<br />

SV001 Poll fail<br />

pgm: --000:00<br />

To modify the poll fail PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

ModBUS Door Control Group<br />

The door control group will define which doors can be controlled by the ModBUS interface if a<br />

door unlock or lock action is requested. The default setting of None allows all doors to be<br />

controlled by the interface.<br />