01.07.2014 Views

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

PRT CTRL Integrated Controller Reference Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SV001 Handshake<br />

time: 030<br />

To modify the handshake time (000 to 255, a setting below 010 will result in the default of 30<br />

seconds being programmed), use the keypad as explained in section Entering Decimal<br />

Numbers on Page 405 and press [ENTER].<br />

Redial Time<br />

The redial time determines inter phone number dialling timeout. A value of 20 seconds is<br />

programmed by default meaning each phone number will be dialled with 20 second intervals<br />

from the time the previous call was terminated.<br />

SV001 Redial<br />

time: 020<br />

To modify the redial time (000 to 255, a setting below 010 will result in the default value of<br />

030 being programmed), use the keypad as explained in section Entering Decimal Numbers<br />

on Page 405 and press [ENTER].<br />

Off Hook PGM<br />

The off hook PGM is activated when the service takes the telephone line and is deactivated<br />

when the service completes communication. This PGM setting can be used with remote<br />

exchange systems that require ground start communication connections.<br />

SV001 Off Hook<br />

pgm: --000:00<br />

To modify the off hook PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

Report OK PGM<br />

The report ok PGM is activated when the service completes the reporting and the messages<br />

have been successfully acknowledge. The PGM is activated when the service returns a<br />

reporting complete result OK message. The PGM is not deactivated and should be<br />

programmed with a time. Connect to an external audible device to signal that the report was<br />

completed. Using this feature with the shorten exit delay for an area allows an end user to<br />

verify the communication path on arming of the protected area.<br />

SV001 Report Ok<br />

pgm: --000:00<br />

To modify the report ok PGM, use the settings as explained in section Entering PGM and PGM<br />

Groups on Page 410.<br />

AMX Home Automation Service<br />

To program the AMX home automation service ensure that the service that has been selected<br />

is halted. Press the [ENTER] key until the display shows the service type selection screen.<br />

227 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!