Use the [1] and [3] keys to scroll the area group selection and press [ENTER] to select the<br />

area group displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Dialling Attempts<br />

The dialling attempts determine how many times the dialler will attempt to dial a number<br />

before failure. This setting will be overridden by the modem configuration dependent on the<br />

country of installation and local phone authority. For UL and ULC installations this value can<br />

not be set above 8. The dialling attempts operate in conjunction with the dialling delay<br />

setting.<br />

SV001 Dialling<br />

attempts: 008<br />

To modify the dialing attempts (000 to 255, a setting of 000 will result in the default of 8<br />

attempts being used), use the keypad as explained in section Entering Decimal Numbers on<br />

Page 405 and press [ENTER].<br />

Port Open Attempts<br />

The port open attempts determine how many times the service will wait for the modem to<br />

become available if another service is already using modem for communication. This operates<br />

in conjunction with the port open time settings.<br />

SV001 Port open<br />

attempts: 008<br />

To modify the port open attempts (000 to 255, a setting of 000 will result in the default of 8<br />

port attempts being used), use the keypad as explained in section Entering Decimal Numbers<br />

on Page 405 and press [ENTER].<br />

Report Count<br />

The report count if set to a value other than 000 will restrict the service from sending more<br />

than the programmed number of reports to the monitoring station. When using multiple<br />

reporting paths that potentially can report the same event to 2 or more locations the report<br />

count should be programmed with an acceptable limit (Between 8 and 16 is recommended).<br />

SV001 Report<br />

count: 000<br />

To modify the report count (000 to 255, a setting of 000 will result in an unlimited number of<br />

reports being able to be sent), use the keypad as explained in section Entering Decimal<br />

Numbers on Page 405 and press [ENTER].<br />

Handshake Time<br />

The handshake time determines the time it takes for the remote receiving unit to answer and<br />

provide a handshake message for the SIA format. By default this is set to 030 seconds and<br />

should only be adjusted if a longer than normal call completion is required. When handshakes<br />

for lower speed formats are placed in front of the SIA handshake it may be required to<br />

increase this time.<br />