Serial Printer Service<br />

To program the serial printer service ensure that the service that has been selected is halted.<br />

Press the [ENTER] key until the display shows the service type selection screen. By default<br />

the serial printer service is programmed at SV004 and is running using the programmed<br />

TCP/IP address and port 10001.<br />

SV001 Ser Type<br />

Serial Printer<br />

Use the [1] and [3] keys to scroll the service types until you reach the serial printer selection<br />

and press [ENTER] to select the serial printer service type displayed and proceed to the next<br />

programmable option for the serial printer service. For more information about the list control<br />

data entry refer to the section List Control Data Entry on Page 406.<br />

Service Mode<br />

The service mode determines how this service operates with the system controller. By default<br />

a service is set to start with the operating system. Setting a service to "Start With The<br />

Operating System" (Start With O/S) allows the service to operate automatically, if the system<br />

controller is reset or restarts the service will automatically restart with the operating system.<br />

<strong>Manual</strong> control of the service can be set by using the <strong>Manual</strong> option for the service mode.<br />

SV001 Ser Mode<br />

Start with O/S<br />

Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select<br />

the operating mode displayed. For more information about the list control data entry refer to<br />

the section List Control Data Entry on Page 406.<br />

Communications Port Number<br />

The communications interface port defines which communications port the controller will use<br />

for communication when talking with the System <strong>Controller</strong>. By default the Protégé SMGT<br />

service is started on IP at port number 10000 and is running by default.<br />

SV001 Port<br />

TCP/IP 1 (10000)<br />

Use the [1] and [3] keys to scroll the communication ports and press [ENTER] to select the<br />

operating mode displayed. For more information about the list control data entry refer to the<br />

section List Control Data Entry on Page 406.<br />

Communications Port Speed<br />

The communications port speed defines the baud rate at which the serial communications will<br />

operate. This has no effect when operating in TCP/IP mode. The default value for serial port is<br />

38400 bits per second. If the speed or configuration is different adjust this setting to suit the<br />

host configuration.<br />

SV001 Speed<br />

9600<br />