poll events are sent to the secondary IP address as poll events are used to<br />

prove the primary connection is active.<br />

Disabled the service will not backup to the secondary IP address on<br />

communication failure.<br />

Option 8 – Backup to Monitor Phone<br />

Enabled the service will attempt to send events to the server using a<br />

monitor phone service (the first available service) if communication fails on<br />

the primary IP address.<br />

Disabled the service will not backup to the monitor phone service on<br />

communication failure.<br />

Server IP Address<br />

The Server IP Address is the IP address of the Protégé System Management Suite that the<br />

<strong>Controller</strong> reports events to when the server is not connected.<br />

SV001 Server IP<br />

000.000.000.000<br />

To modify the IP address use the keypad as explained in section Entering Decimal Numbers<br />

on Page 405. Press [ENTER] to save the Octet that is being entered and move to the next<br />

Octet or the next screen once all four have been completed.<br />

Server Port<br />

The server port configures the service with the remote port number to communicate on.<br />

SV001 Server<br />

port: 10002<br />

To modify the TCP/IP port (00000 to 65535), use the keypad as explained in section Entering<br />

Decimal Numbers on Page 405 and press [ENTER].<br />

Backup IP Address<br />

The Backup IP Address is the Backup IP address of the Protégé System Management Suite<br />

that the <strong>Controller</strong> reports events to when the server is not connected. Note that this is not a<br />

separate server, rather an alternate path for communicating with the server.<br />

SV001 Backup IP<br />

000.000.000.000<br />

To modify the IP address use the keypad as explained in section Entering Decimal Numbers<br />

on Page 405. Press [ENTER] to save the Octet that is being entered and move to the next<br />

Octet or the next screen once all four have been completed.<br />

Backup Port<br />

The backup port configures the service with the remote port number to communicate on.<br />

215 Protégé <strong>Integrated</strong> System <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong>